Brand: ok - power models: OKPF - 375 - m
Power: 350 W
The input signal: AC100-250 - v
Color: silver
Detailed description:
Features:
Full voltage input: AC100-47-250 v / 63 hz
Compact design, small size
Protection function: SCP/OCP/OTP
High reliability, low power consumption, high efficiency
Input/output is completely isolated
100% full load aging
1 year warranty
Technical specifications:
Project parameters
Lose out
The output
A DC27V output voltage
The rated current is 3.5 A
Ripple noise (Vp - p) 80 mv
24.0-28 v output voltage adjustable range
Linear adjustment rate was 0.4%
0.4% load regulation
Output the output voltage of DC12V
The rated current is 2 a
Linear adjustment rate was 0.3%
0.3% load regulation
Output three DC380V + 10 v output voltage (with the input isolation)
The rated current is 0.6 A
Ripple noise (Vp - p) 10 v
The startup time < 2.0 S @ 115 vac < 2.0 S @ 230 vac at Full load
Maintain time > 20 ms @ 230 vac at Full load
Lost in the
To lose
Into the AC100-240 v input voltage
47-63 hz frequency
Efficiency of 86% @ 230 vac
3.2 A @ 100 vac input current (MAX)
Surge current < 30 a @ 230 vac, full of cold start
Leakage current < 0.5 mA @ 230 vac
To protect
Burp S.C.P OUT1 type protection, automatic recovery
O.C.P OUT1 130% Iout
45 ℃ environment temperature 0-100% load and 70% load > 45 ℃
Storage temperature - 20-85 ℃
Temperature rise < K80
Reference standard EN60950 safety standards; GB4943; UL60950
Withstand voltage I/P - O/P: 1.5 KVAC I/P - FG: 1.5 KVAC O/P - FG: 0.5 KVAC
Insulation resistance I/P - O/P, I/P - FG, O/P - FG: 100 m or higher Ω / 500 VDC
EMI conduction and radiation Meet FCC. PART15. CLASS B; EN55022 CLASS B
Meet EMC standard GB/T 17626.4, 5 LEVEL3 EN61000-4-4, 5 LEVEL3
Other exterior size (L * W * H) mm 155 * 82 * 50
Natural air cooling mode
Connection terminals output: XY306A, input: XY305B
Weight & packing
Note: all technical parameters test condition no special statement is on by default: input AC230V, output rated load and measured under the condition of the environment temperature is 25 ℃. Ripple noise test conditions: open 20 MHZ bandwidth limitations, the ends of the test probe 0.1-47 uf capacitance in parallel. Switching power supply as a whole machine equipment one of the accessories, if need EMC certification, the machine equipment need to do EMC standards certification.
OUT3 - PFC (DC380V) maximum output power 350 w, output for PFC as OUT1 and OUT2 level before input, OUT3 - PFC (DC380V) of actual load for maximum output power (350 w) - the OUT1 and OUT2 output power